UK to EU Shipping: We will dispatch all EU orders from Belgium. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES UK to USA Delivery, No Hassle, Directly from the manufacturer. UK to Australia & New Zealand Shipping: We will dispatch all Orders from Australia. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES UK to EU Shipping: We will dispatch all EU orders from Belgium. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES UK to USA Delivery, No Hassle, Directly from the manufacturer. UK to Australia & New Zealand Shipping: We will dispatch all Orders from Australia. NO HASSLE, NO TAX, NO DUTY, NO EXTRA CHARGES

Categories

Delta MDS-350AD701 350W medical ATX PSU rear view showing AC inlet, switch, and cooling fan
Delta MDS-350AD701 350W medical ATX PSU rear view showing AC inlet, switch, and cooling fan

Delta MDS-350AD701 350W, 12V Medical ATX 1U Power Supply

2 Years Warranty

UK Free Shipping UK Free Shipping over £249


Buy 5 or More Units - Unlock Priority Discounts!
Buy 20 or More Units - Get Exclusive Volume Discounts!


Also Support: Google & Apple Pay

Are you a reseller or placing a large order?
We're happy to offer Special Pricing tailored to your needs.
Click "Request Quote" or email us at [email protected] to get your best price today!

Add to Wishlist

Compare

Product Code: PSEL-240

MPN #: MDS-350AD701

Power cuts and unstable voltages can ruin critical work, especially in medical or industrial settings. The Delta MDS-350AD701 350W, 12V Medical ATX 1U Power Supply delivers a reliable 350 W of clean 12 V power, keeping your computers, workstations or controllers running smoothly without flicker or unexpected drops, so you never lose data again.

Delta MDS-350AD701 350W, 12V Medical ATX 1U Power Supply - a steady solution for demanding environments

When a system loses power, you risk data loss, equipment damage and costly downtime. This is especially true for medical devices and precision industrial equipment where reliability is non-negotiable. The Delta MDS-350AD701 350W, 12V Medical ATX 1U Power Supply solves the problem by providing universal AC input, active PFC and multiple safety certifications, ensuring continuous operation even under fluctuating mains conditions. Its compliance with IEC 60601-1 and IEC 62368-1 means you meet strict medical and ITE safety standards without extra hassle.

Benefits

Experience real advantages in everyday use:

  • Consistent 350 W output prevents system crashes during critical tasks.
  • Active PFC improves energy efficiency and reduces electricity costs.
  • Dual-MOPP isolation protects both patient and equipment from electric shock.
  • Wide input range (90-264 Vac) lets you operate worldwide without adapters.
  • Certified RoHS compliance supports environmentally responsible installations.

Usages of Delta MDS-350AD701 350W, 12V Medical ATX 1U Power Supply

This power supply is ideal for medical imaging stations, patient monitoring consoles, laboratory automation rigs, and rugged industrial controllers that require ATX 12 V compatibility and strict safety approvals. Its 1U form factor fits easily into standard rack cabinets, making it a perfect fit for space-constrained server rooms or mobile diagnostic units.

Key Features of Delta MDS-350AD701 350W, 12V Medical ATX 1U Power Supply
  • Input Voltage Range: 90-264 Vac. Handles a broad spectrum of mains supplies for global use.
  • Nominal Input Voltage: 100-240 Vac. Guarantees stable operation across typical voltage levels.
  • Full Load Efficiency: 82 % @ 115 Vac / 60 Hz, 85 % @ 230 Vac / 50 Hz. Delivers high efficiency, lowering heat and power bills.
  • Power Factor: 0.90 minimum. Ensures good power quality and reduces strain on the electrical network.
  • Output Power: 350 W. Provides ample headroom for demanding ATX 12 V systems.
  • Dimensions: 194 × 100 × 40.5 mm (7.64 × 3.94 × 1.59 in). Compact size fits standard 1U racks.
  • Unit Weight: 1.2 kg (2.6 lb). Light enough for easy installation and handling.
  • Cooling System: Forced Cooling. Keeps the unit at optimal temperature even under continuous load.
  • Overload/Overcurrent Protection: Latch Mode for +3.3 V, +5 V, +12 V outputs, Auto-recovery for +5 Vsb. Safeguards your equipment from excess current.
  • IEC 60601-1-2 4th Ed. Compliance: Meets the latest electromagnetic compatibility requirements for medical devices.

Specifications
Input Ratings / Characteristics  
Nominal Input Voltage 100–240 Vac
Input Voltage Range 90–264 Vac
Nominal Input Frequency 50–60 Hz
Input Frequency Range 47–63 Hz
Input Current (max) 6 A
Input Surge Voltage (max) 300 Vac for 100 ms
Full load Efficiency (typ.) 82% @ 115 Vac / 60 Hz
85% @ 230 Vac / 50 Hz
Inrush Current (max) No damage, cold start
Leakage Current (max) 0.1 mA @ NC0.3 mA @ SFC
Output-PE (protective earth) Leakage current for BF application (max) 0.1 mA @ NC, 0.5 mA @ SFC
Power Factor (min) 0.90 @ 115 V / 50 Hz, 230 V / 50 Hz, full load
Output Ratings / Characteristics  
Nominal Output Voltage (V rated) +12 V1, +12 V2, +5 V, +3.3 V, +5 Vsb, -5 V, -12 V
Output Power 350W
Line Regulation (max) ±0.5%
Start-up Time (max) (Remote On_Off @ TTL Low, then AC applied) 1000 ms @ 115 Vac
Hold-up Time (min) 17 ms @ 115 Vac / 60 Hz
Dynamic Response (Overshoot & Undershoot O/P Voltage) ±10% @ 50–100% load
Rise Time (max) 20 ms
Remote On_Off/INHIBIT TTL Active Low: Output Enable
TTL Active High: Output Disable
Mechanical  
Case Chassis SECC (Steel, Electrogalvanized, Cold Rolled, Coil)
Case Cover SECC (Steel, Electrogalvanized, Cold Rolled, Coil)
Dimensions (L × W × H) 194 × 100 × 40.5 mm (7.64 × 3.94 × 1.59 inch)
Unit Weight (typ.) 1.2 kg (2.6 lb)
Cooling System Forced Cooling
Environment  
Surrounding Air Temperature Operating: 0 °C to +50 °C
Storage: -40 °C to +85 °C
Operating Humidity 5–95% RH (Non-Condensing)
Operating Altitude 5,000 meters (16,400 feet)
Shock Test (Non-Operating) 50 G, 11 ms, 3 shocks for each direction
Vibration (Operating) 5–500 Hz, 2 Grms, 15 minutes for each of three axes
Protections  
Overvoltage For +3.3V output, Maximum voltage < 4.8V
For +5V output, Maximum voltage < 7V
For +12V1 & +12V2 outputs, Maximum voltage < 16V
Protection Method: Latch Mode
For +5Vsb output, Maximum voltage < 10V
Protection Method: Latch Mode
Overload / Overcurrent For +3.3V output, Maximum current < 25A
For +5V output, Maximum current < 25A
For +12V1/+12V2 output, Maximum current < 25A
Protection Method: Latch Mode
For +5Vsb output, Maximum current < 5A
Protection Method: Auto-recovery Mode
Over Temperature Protection Method: Latch Mode
Short Circuit +3.3V, +5V, +12V1 and +12V2, Protection Method: Latch Mode+5Vsb
Protection Method: Auto-recovery
Reliability  
MTBF 500 K hrs based on Telecordia SR-332
Expected Cap Life Time 26,280 hrs
Safety  
Electrical Safety IEC60950-1 (Ed.2,2005) & IEC 62368-1 CB report
CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015
Medical Safety IEC 60601-1
EN60601-1
CAN/CSA-C22.2 No. 60601-1
ANSI/AAMI ES60601-1
Galvanic Isolation Input to Output (2XMOPP): 4000 Vac
Input to/Ground (1XMOPP): 1500 Vac
Output to/Ground (1XMOPP): 1500 Vac (Type BF application rated)
UKCA In conformance with Electrical Equipment (Safety) Regulations 2016
Electromagnetic Compatibility Regulations 2016
Medical Devices Regulations 2002 (UK MDR 2002)
EMC  
Emission EN/BS EN 55011 & Compliant with EN/BS EN 55032, FCC Title 47: Class B
Harmonic Current Emissions IEC 61000-3-2: Meet Class D limit
Voltage Fluctuation and Flicker IEC 61000-3-3
ESD Immunity IEC 61000-4-2
Radiated Immunity IEC 61000-4-3
IEC 60601-1-2
EFT IEC 61000-4-4
Surge IEC 61000-4-5
Conducted Immunity IEC 61000-4-6
Magnetic Field IEC 61000-4-8
Voltage Dips IEC 60601-1-2
IEC 61000-4-11
Downloads

Customer Reviews

Be the first to write a review

You can upload up to 3 images (JPG or PNG formats only).
Please fill the reCAPTCHA.
Please fill the reCAPTCHA.
🍪 Cookies Notice

We use cookies to ensure you get the best experience. See our Privacy Policy.